Single-point inline oil condition monitor. Plug-and-play installation on individual assets via bypass line. Delivers continuous real-time MIR spectroscopy and viscosity analysis — configurable for mineral oils, PAO, PAG, Phosphate Ester, Polyolester and water-based emulsions. No sampling. No lab delays. Data in the same format and units as standard oil analysis laboratory reports.
The PLUS installs directly into the oil circuit bypass line via pump or electric valve. Powered from 24V DC or 100–240V AC, it delivers continuous MIR and viscosity measurements with all results in standard laboratory units.
The PLUS monitors the parameters that matter most for predictive maintenance and condition-based oil change decisions — application-configured prior to delivery.
Early detection of water ingress before emulsification or corrosion damage occurs.
Continuous kinematic viscosity measurement detects thinning, thickening, and shear degradation.
Quantifies oxidative degradation of the base oil, a primary indicator of remaining useful life.
Total Acid / Base Number monitoring for engine and industrial lubricant degradation assessment.
Detects sulphation byproducts in engine oils, particularly relevant for diesel and gas engine applications.
Measures soot loading in diesel and gas engine lubricants to prevent accelerated wear and filter blockage.
Detects fuel contamination of engine oil — a leading indicator of injector faults or piston ring wear.
Tracks depletion of antioxidant additive packages, enabling condition-based oil change decisions.
The PLUS is deployed on a wide range of rotating and reciprocating machinery where continuous oil condition data reduces unplanned downtime and optimises maintenance intervals.